Expertise of University have researched and collected Study Material 212iLM Keypad Installation & Programming Instructions study material in pdf format. This pdf formatted University Study Material 212iLM Keypad Installation & Programming Instructions covered the subject concepts in a comprehend manner for easy reference to their students.  

University

University
Academic year: 2023
Related Courses
Preview text

6-051344 X2 1212iLM Keypad Installation & ProgrammingPRINTER’S INSTRUCTIONS:

INSTR/PROG,212ILM-AL/212ILM-BZ - P/N: 6-051344 X2 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT 17.000” X 11.000” FOLD ED 8.500” X 11.000” - TOLERANCE: ± .125” - SCALE: 1-1Speci fi cationsCase Dimensions:

6-1/2” L x 1-3/4” W x 1-1/8” DElectrical:

Voltage: 12-24 VAC/DCCurrent:

53mA@12VDC72 mA @ 24 VDC95 mA@12 VAC108 mA @ 24 VACRelay Contacts:

Main Relay (controller): 2 AmpsBell Relay:

Form A; 1 Amp @ 30 VAC/DCEnvironmental:

-20º F to 130° FFor Indoor and Outdoor UseFeatures ●120 User Capacity ●Programmable Relay Time (0 to 99 seconds) ●Request to Exit (REX) Input ●Vandal Resistant Case

●Sealed for Indoor or Outdoor Applications ●LED’s for Relay Status Indication ●Bell Output ●Surface Mount ●Illuminated Hardened Keys

●Rated for Greater than One Million Key CyclesApplications ●Low to Medium/Heavy Traf fi c Areas ●Rough Service Environments ●Mullion Frame Mounting

●Dimly Lit AreasDescription:

The Door  ♦ Gard Series 212iLM keypad combines elegant looks with a mullion mount design in a rugged, vandal resistant case, which you can use for almost any application. The 212iLM has hardened backlit keys designed to perform in medium to high traf fi c areas and in rough duty environments. The electronics are also conformal coated, which makes the keypad suitable for indoor or outdoor applications.

Basic Operation:To gain access through the door enter your code (1-6 digits) followed by the ✱ key on the keypad.

Packing List:(1) 212iLM Keypad(1) Eight-Conductor Wire Harness(1) Mullion Hardware Pack(1) 5/64” Allen Wrench(1) Anti-Oxidant Grease Pack(1) Installation/Programming ManualWire Harness Con fi guration:

Pin Wire Color Signal Name1 Red Power (+)2 Black Power (-)3 White/Black REX4 White/Yellow Main Relay NC5 Blue Main Relay Common6 Brown Main Relay NO7 White Bell Relay Contact (A)8 White Bell Relay Contact (B)212iLM KeypadInstallation & Programming InstructionsNote: This product is designed to be installed and serviced

by security and lock industry professionals.

2 6-051344 X2212iLM Keypad Installation & ProgrammingKeypad Installation Procedure:

Step 1: Drill through the back plate using a 11/64” bit. Use the template on the back page to accurately mark the mounting holes before drilling. Then drill the mounting holes with a 9/64” drill bit. Also drill the hole for the wires. This may vary depending on the number of conductors required. Refer to mounting height below.

Step 2: Wire the keypad using the diagrams in the following sections.

Step 3: Mount the 2121iLM keypad onto the mounting surface using the provided screws. Do no over-tighten the screws, which may result in damage.

Keypad Mounting HeightMounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on center off the fl oor.

6-051344 X2 3212iLM Keypad Installation & ProgrammingWiring an Electromagnetic Lock (Maglock)1. Connect the red (V+) and black (V-) wires to your power supply.

2. Connect the blue wire (relay common) to positive on your power supply.3. Connect the white/yellow wire (relay normally closed) to the positive connection on your maglock.4. Connect negative connection on your maglock to the negative on the power supply.

Basic Access Control Using an Electric Door Strike1. Connect the red (V+) and black (V-) wires to your power supply.2. Connect the blue wire (relay common) to positive on your power supply.3. Connect the brown wire (relay normally open) to the positive connection on your door strike.4. Connect negative connection on your door strike to the negative on the power supply.

A fi ltered and regulated DC power supply is recommended.

A fi ltered and regulated DC power supply is recommended.

4 6-051344 X2212iLM Keypad Installation & ProgrammingShunting a Normally Closed Zone1. Connect the red (V+) and black (V-) wires to your power supply.

2. Connect the blue wire (relay common) to the common connection on the alarm contacts.3. Connect the brown wire (relay normally open) to the normally open connection on the alarm contacts.

Wiring a Request to Exit Device (REX)The 212iLM is equipped with a REX input. The normally open REX input triggers the main relay for the amount of time you programmed for the master code. If the master code is set to toggle, the REX only triggers the relay for 5 seconds. There is no programming required for the REX to operate.

1. Connect the red (V+) and black (V-) wires to your power supply.

2. Connect the common connection on the REX device to the negative on your power supply.3. Connect the white/black wire to the normally open connection on the REX device.

A fi ltered and regulated DC power supply is recommended.

A fi ltered and regulated DC power supply is recommended.

6-051344 X2 5212iLM Keypad Installation & ProgrammingWiring the Bell Output to a Speaker:

The 212iLM keypad has a built in bell button, which triggers a relay output when pressed. This relay is normally open and the contact closes when triggered. You can use this relay output to trigger devices that require a momentary closure, such as a doorbell. The relay output provides a dry contact, but you can run up to 30 volts AC/DC through it for devices that require power to operate. The diagram below shows these connections.

6 6-051344 X2212iLM Keypad Installation & ProgrammingProgramming the 212iLM KeypadTo program the 212iLM you fi rst must enter program mode.

To enter program mode enter the following on the keypad: 99 # master code ✱ (default master code is 1234).

Keypad Default SettingsOption Default Setting Option Default SettingMaster Code 1234 Main Relay Time 5 SecondsAudio Keypress Feedback Enabled Visual Keypress Feedback EnabledAuto-Entry Disabled Door Bell Select ContinuousKeypad Illumination Enabled Keypad Dimming EnabledProgramming Options ChartCommand/Action Keys to Enter/Details

Change Master Code 1 # new code ✱ new code ✱Change Main Relay Time relay time # 1 # master code ✱ master code ✱Add/Change Useruser location # new code ✱ new code ✱Note: Users programmed with this command use master code relay time.

Add Toggle User 00 # user location # new code ✱ new code ✱Add User with Speci fi c Relay Time relay time # user location # new code ✱ new code ✱Command 30Set/Clear Keypad Options(options below, defaults in bold )30 # option # set/clear # ✱ ✱Option Clear Set

0 – Audio Keypress Feedback 0 = Disabled 1 = Enabled1 – Visual Keypress Feedback 0 = Disabled 1 = Enabled2 – Auto-Entry 0 = Disabled 1 = Enabled3 – Keypad Illumination 0 = Disabled 1 = Enabled4 – Keypad Dimming 0 = Disabled (always bright) 1 = Enabled

5 – Door Bell Select 0 = Disabled 1 = EnabledCommand 32Set Bell Output Time32 # 0 # time # ✱ ✱ Set timed output (1 – 99 seconds)32 # 0 # 0 # ✱ ✱ Set to continuousCommand 46

Reset Keypad to Default Settings46 # 00000 # 00000 # ✱ ✱Exit Program Mode Press the ✱ KeyNotes:

1. The 212iLM can store 120 user codes, including the master code. Codes can be from 1 to 6 digits long.

2. When auto-entry is enabled, users with codes the same length as the master code do not have to press the ✱ key after entering their code to enter the door.

3. When keypad dimming is disabled the backlighting remains at full intensity (does not dim).4. When the door bell output is set to continuous the relay is energized as long the door button is pressed. When you release the button the relay de-energizes.

6-051344 X2 7212iLM Keypad Installation & ProgrammingProgramming ExamplesChanging the Master CodeThe following example show how to change the master code to 4875 from the default of 1234.

1. Enter Program Mode 99 # 1234 ✱2. Program New Master Code 1 # 4875 ✱ 4875 ✱3. Exit Program Mode ✱Changing the Main Relay TimeThe following example shows how to change the main relay time. The master code is 4875.

1. Enter Program Mode 99 # 4875 ✱2. Change the Main Relay Time 10 # 1 # 4875 ✱ 4875 ✱3. Exit Program Mode ✱Adding User CodesThe following example shows how to program user 2 with a code of 1749 and user 3 with 9328. The master code is 4875.

1. Enter Program Mode 99 # 4875 ✱2. Program User # 2 2 # 1749 ✱ code ✱3. Program User # 3 3 # 9328 ✱ code ✱4. Exit Program Mode ✱Programming a Toggle User

The following example shows how to program user 4 as a toggle user with a code of 98773. The master code is 4875.

1. Enter Program Mode 99 # 4875 ✱2. Change the Main Relay Time 00 # 4 # 98773 ✱ 98773 ✱3. Exit Program Mode ✱LED IndicationsLED State Description

Red Solid Door LockedGreen Solid Door UnlockedYellow Solid Programming ErrorYellow Flashing Slowly Program ModeYellow Momentary Flash Visual Keypress Feedback8 6-051344 X2212iLM Keypad Installation & ProgrammingTroubleshootingIssue Explanation Solution

LED’s cycling slowly from right to left.The 212iLM Mullion is designed to monitor for low voltage. Once low voltage is detected, the keypad turns off the backlighting to ensure operation of the keypad until the problem can be attended to.Verify the power supply output voltage. If it is below the voltage threshold of 7.5 Volts AC or 9 Volts DC, you must increase the voltage to between 12-24 Volts.

LED’s cycling rapidly from left to right and the keypad has lost all operation.The 212iLM Mullion is designed to monitor for over voltage. This is a very “severe” condition and signi fi cantly affects the keypad’s operation. Once the over voltage is detected, the keypad shuts down all operation and does not operate until the voltage is lowered.Verify the power supply output voltage. If it is over the voltage threshold of 35 Volts, you must lower the voltage below 29 Volts.

Can’t access programming mode using the master code.The code you are entering is likely not the master code.Perform the program mode loopback in the following section to enter program mode and reprogram the master code.

No LED’s are lit on the keypad. Power is not reaching the keypad. First verify there is voltage at the keypad. If not, verify there is voltage at the power supply. If there is voltage, verify continuity on the wires out to the keypad. Otherwise contact the power supply manufacturer or Nortek Security & Control if there is a problem with the keypad. You also may try power the keypad with a 12V battery to verify operation.

DEALERS/INSTALLERS ONLY! End users must contact the dealer/installer for support. If the keypad still does not work after troubleshooting, please call the Technical Services department at 1-800-421-1587.

Testing the KeypadAfter installing the keypad, it is recommended that you perform the keypad self-test once a year, to ensure that the keypad is working properly.

●To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890 # 123456 ✱ ●If all 12 key presses are accepted, the keypad enters self-test mode.

●The LEDs alternate three times followed by the sounder beeping three times.

6-051344 X2 9212iLM Keypad Installation & ProgrammingProgram Mode LoopbackIf you’ve forgotten the local program code use the following loopback connection to enter program mode. Power down the unit, short the wires in the con fi guration illustrated, then power the unit back up. The yellow LED should be fl ashing.

Now change your local program code or reset the unit. Power the keypad down and reconnected the wire harness in the original con fi guration.

10 6-051344 X2212iLM Keypad Installation & ProgrammingLimited WarrantyThis Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24) months. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control or through Nortek Security & Control’s normal distribution channels. Nortek Security & Control does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There

are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or pro fi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied

warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Nortek Security & Control LLC Warranty is in lieu of all other warranties express or implied.

All products returned for warranty service require a Return Authorization Number (RA#). Contact Returns at 1-855-546-3351 for an RA# and other important details.

6-051344 X2 11212iLM Keypad Installation & ProgrammingPAGE LEFT BLANK INTENTIONALLY12 6-051344 X2212iLM Keypad Installation & Programming212ilM Mounting TemplateCopyright © 2015 Nortek Security & Control LLC